Gablonzer Straße 38 37,620 SF of Industrial Space Available in Oberursel (Taunus), HES 61440
ALL AVAILABLE SPACE(1)
Display Rental Rate as
- SPACE
- SIZE
- TERM
- RENTAL RATE
- SPACE USE
- CONDITION
- AVAILABLE
TECHNICAL OVERVIEW CERTIFICATIONS • TÜV Green IT / Energy-Efficient Data Center Premium Certificate • ISO22301 (to be checked) • TÜV TSI Standard 4.6 Level 4 • TÜV TSI Standard 4.6 Dual Site Level 4 • ISAE3402 NETWORK CONNECTIVITY • Colt • Deutsche Telekom • Versatel • British Telecom • GNPP Connectivity • EU Networks • Verizon • DESIGN LEVEL Kyndryl Design Level 4 [Comparable to Uptime Tier 4, all infrastructure supply components 2N (N+N)] • TOTAL BUILDING Nine separate underground IT compartments, IT area and infrastructure area physical separated • TOTAL WHITE SPACE 3,495 sqm / 37,620 sq ft • GRID CONNECTION Dual 20 kV utility lines from separate substations with different routes • UPS & GENERATOR Eight 2.200 kVA diesel generators • COOLING Cooling with eight 1300 kW York chillers and free cooling • PCI DSS (to be checked) • ISO 27001 • ISO 9001 (to be checked) • ISO 50001 • EU Code of Conduct
- Fits 95 - 292 People
| Space | Size | Term | Rental Rate | Space Use | Condition | Available |
| 1st Floor | 37,620 SF | Negotiable | Upon Request Upon Request Upon Request Upon Request | Industrial | - | 30 Days |
1st Floor
| Size |
| 37,620 SF |
| Term |
| Negotiable |
| Rental Rate |
| Upon Request Upon Request Upon Request Upon Request |
| Space Use |
| Industrial |
| Condition |
| - |
| Available |
| 30 Days |
1st Floor
| Size | 37,620 SF |
| Term | Negotiable |
| Rental Rate | Upon Request |
| Space Use | Industrial |
| Condition | - |
| Available | 30 Days |
TECHNICAL OVERVIEW CERTIFICATIONS • TÜV Green IT / Energy-Efficient Data Center Premium Certificate • ISO22301 (to be checked) • TÜV TSI Standard 4.6 Level 4 • TÜV TSI Standard 4.6 Dual Site Level 4 • ISAE3402 NETWORK CONNECTIVITY • Colt • Deutsche Telekom • Versatel • British Telecom • GNPP Connectivity • EU Networks • Verizon • DESIGN LEVEL Kyndryl Design Level 4 [Comparable to Uptime Tier 4, all infrastructure supply components 2N (N+N)] • TOTAL BUILDING Nine separate underground IT compartments, IT area and infrastructure area physical separated • TOTAL WHITE SPACE 3,495 sqm / 37,620 sq ft • GRID CONNECTION Dual 20 kV utility lines from separate substations with different routes • UPS & GENERATOR Eight 2.200 kVA diesel generators • COOLING Cooling with eight 1300 kW York chillers and free cooling • PCI DSS (to be checked) • ISO 27001 • ISO 9001 (to be checked) • ISO 50001 • EU Code of Conduct